Sampling
- Qualified sampling of home dust acc. to German VDI 4300, page 8 andGerman VDB guideline II B3
- Qualified sampling of bulk samples acc. to German VDB guideline II B 2
- Qualified air measurements acc. to German VDI 4300, page 2 & page 4 and DIN EN ISO 16000, page 12 (PCP, dioxine in indoor rooms)
- Qualified air measurements acc. to German DIN ISO 16000, page 13 (PCP, dioxine in indoor rooms)
- Qualified air measurements acc. to German VDI 3498, page 1 and page 2 (dioxine in indoor rooms, filter methode)
- Qualified air measurements acc. to German VDI 4301, page 3 (PCP, Lindan) and page 4 (pyrethroide in air, home dust and wish probes)
Analysing/Determination
- Determination of PCP, DDT, Lindan, Pyrethroide in home dust (analysing with GC/MS)
- Determination of PCP, DDT, Lindan in bulk samples (analysing with GC/MS)
- Determination of PCP, dioxines in indoor room filter probes acc. to German VDI 4301, page 2 (GC/MS method) und page 3 (GC/ED method) or NIOSH 5502
- Determination of PCP, dioxines in indoor room filter probes acc. to German DIN ISO 16000, page 14
- Determination of dioxines in indoor romm filter rpbes acc. to German VDI 3498, page 1 and page 2
- Determination of pyrethroides in indoor room filter probes acc. to German VDI 4301, page 4
Expertise
- Consulting
- Inspection on site, determination of hazardous substances
- Evaluation of measurement results acc. to German BGIA, AGÖF and VDB
- Necessity of cleaning acc. to German „PCP-Richtlinie“
- Risk assessment acc. to German „Gefahrstoffverordnung“, AGÖF and VDB
- Reports & Expertises
Biocide
Substances
Pentachlorphenol (PCP), Hexachlorbenzol (HCB), Lindan, Dichlordiphenyltrichlorethan (DDT),
Permethrin, Chlornaphthaline
Application
Wood protection agents, paints and coatings, adhesives, textiles und leather, pesticides, moth control products, insecticide
Function
Fungizide, wood protection agents, insecticide
Appearance
Roof timbering (beams, roof battens), wall and top plates, wood floors, parquet, furnitures, impregnated clothing, leather goods, old coatings
Function
Water proofing, building protection, wood protection
Risks
Some agents carcinogen, mutagenic, teratogenic, acut toxic, neurotoxic, immun toxic
Secundary contamination possible
Reason for determinations
Health problems (headache, stomachache, dizziness, lassitude, sickness, etc.)
Evaluation of the necessity of cleaning
Success control of cleaning